Level control with visual and acoustic warning
Beneficii și caracteristici
- Warning light with acoustic signal
- Application range up to 250°C
- Teflon probe can be used horizontally or vertically
Date tehnice
Domenii de aplicare
Opis
The level control is equipped with a warning light and a horn, which give a visual and acoustic warning if the hot-melt adhesive in the tank drops critically.
The Teflon probe is mounted into the melting tank. The necessary borehole is drilled during the production process of the melter. Subsequent fitting into a system that has already been installed is therefore very costly.
Depending on the customer’s application, the Teflon probe is inserted into the melting tank individually in accordance with customer specifications and the required melting capacity.
The active zone on the switching amplifier is calibrated by the customer in accordance with the melt adhesive used in the HB 4000. Subsequently, the drop-out delay is set to send a signal to the output of the switching amplifier and thus to the lamp and the horn.
- Warning light with signal tone
- Teflon probe can be used horizontally or vertically
- Switching amplifier
- Sensor
- Retaining plate for switching amplifier
- Sealing washers for sensor
- Teflon probe capacitive based on the capacitor principle
- Reacts to the approach of the hot-melt adhesive
- Reversible pulses on switching amplifier
- Active zone / Switching range 2 – 10 mm
- Usable length in the tank 39.5 mm
- Teflon probe Ø G ¾“
- Drop-out delay adjustable from 0.1 to 5 seconds
- Calibration on the switching amplifier
- Switching amplifier protection class IP 54